# new_gaussian_control

Source: https://docs.q-ctrl.com/references/qctrl-open-controls/qctrlopencontrols/new_gaussian_control

```python
qctrlopencontrols.new_gaussian_control(rabi_rotation, segment_count, duration, width, name=None)
```

Generates a Gaussian driven control sequence.

Gaussian driven controls mitigate leakage out of the qubit subspace.

### Parameters
* **rabi_rotation** (*float*) – Total Rabi rotation $\theta$ to be performed by the driven control.
* **segment_count** (*int*) – Number of segments in the control sequence.
* **duration** (*float*) – Total duration $t_g$ of the control sequence.
* **width** (*float*) – Width (standard deviation) $\sigma$ of the ideal Gaussian pulse.
* **name** (*str* *,* *optional*) – An optional string to name the control. Defaults to `None`.
### Returns
A control sequence as an instance of DrivenControl.
### Return type
[DrivenControl](https://docs.q-ctrl.com/references/qctrl-open-controls/qctrlopencontrols/DrivenControl.md#qctrlopencontrols.DrivenControl)

### SEE ALSO
[`new_modulated_gaussian_control`](https://docs.q-ctrl.com/references/qctrl-open-controls/qctrlopencontrols/new_modulated_gaussian_control.md#qctrlopencontrols.new_modulated_gaussian_control), [`new_drag_control`](https://docs.q-ctrl.com/references/qctrl-open-controls/qctrlopencontrols/new_drag_control.md#qctrlopencontrols.new_drag_control)

## Notes

A Gaussian driven control <sup>[1](#id2)</sup> consists of a piecewise constant approximation
to an ideal Gaussian pulse:

$$
\mathcal{E}_G (t) = A \exp \left[- \frac{(t - t_g/2)^2}{2\sigma^2}\right] - B
$$

where the two additional parameters $A, B$ chosen such that
$\int_{0}^{t_g} \mathcal{E}_G \,dt = \theta$ and $\mathcal{E}_G(0) = 0$.

Relative values of segments are determined by sampling the ideal Gaussian at the midpoints
of the segments.

## References

* <a id='id2'>**[1]**</a> [Motzoi, F. et al. Physical Review Letters 103, 110501 (2009)](https://doi.org/10.1103/PhysRevLett.103.110501)