# boulderopalscaleup.routines.ResonatorMapping

Source: https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/routines/ResonatorMapping

```python
class boulderopalscaleup.routines.ResonatorMapping(*, feedlines=None, run_mixer_calibration=True, clear_observed_resonances=False, spectroscopy_powers=None, spectroscopy_biases=None, spectroscopy_frequency_step=None, measure_waveform=None, shot_count=250)
```

Parameters for running a resonator mapping routine.

### Variables
* **feedlines** (*list* *[* *str* *] or* *None* *,* *optional*) – The feedlines to target in the routine.
  If not provided, all feedlines in the device will be targeted.
* **run_mixer_calibration** (*bool* *,* *optional*) – Whether to run mixer calibrations before running each program. Defaults to True.
* **clear_observed_resonances** (*bool* *,* *optional*) – Whether to ignore observed resonances for feedline discovery. Defaults to False.
* **spectroscopy_powers** ([*RangeIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/RangeIterable.md#boulderopalscaleup.common.RangeIterable) *or* [*LinspaceIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/LinspaceIterable.md#boulderopalscaleup.common.LinspaceIterable) *or* *None* *,* *optional*) – The power sweep range used during resonator power spectroscopy.
  If not provided, the routine will use its default power sweep.
* **spectroscopy_biases** ([*RangeIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/RangeIterable.md#boulderopalscaleup.common.RangeIterable) *or* [*LinspaceIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/LinspaceIterable.md#boulderopalscaleup.common.LinspaceIterable) *or* *None* *,* *optional*) – The bias sweep range used during resonator bias spectroscopy.
  If not provided, the routine will use its default bias sweep.
* **spectroscopy_frequency_step** (*float* *or* *None* *,* *optional*) – The frequency step size in Hz used during resonator spectroscopy experiments.
  If not provided, the routine will use its default frequency step.
* **measure_waveform** ([*ConstantWaveform*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/ConstantWaveform.md#boulderopalscaleup.common.ConstantWaveform) *or* *None* *,* *optional*) – The measurement pulse used during the initial feed-line discovery experiment.
  If not provided, the routine will use its default measure waveform.
* **shot_count** (*int* *,* *optional*) – The number of repetitions per frequency point. Defaults to 250.