# boulderopalscaleup.routines.OneQubitRecalibration

Source: https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/routines/OneQubitRecalibration

```python
class boulderopalscaleup.routines.OneQubitRecalibration(*, transmon, gate, repetitions=None, force_rerun=False, run_rb=True, run_stark_phase_cal=True, run_voltage_bias_fine_tune=False)
```

Parameters for running the one-qubit recalibration routine.

This is a lighter, periodic variant of [`OneQubitCalibration`](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/routines/OneQubitCalibration.md#boulderopalscaleup.routines.OneQubitCalibration) that
assumes every qubit has already been calibrated at least once. It therefore
persists the existing gate duration (no duration optimization), runs the
fine-frequency Ramsey first (falling back to a coarse Ramsey only when the
fine step fails), and starts the fine-amplitude and Stark-phase calibrations
at their maximum repetitions, decreasing them only when they cannot converge.
A successful run ends with one-qubit randomized benchmarking.

The drive amplitude is likewise persisted, with one exception: if the
fine-amplitude loop cannot converge, the routine escalates once to a Power
Rabi at the persisted duration to re-fit the amplitude, then re-runs the
fine-amplitude loop and re-measures the Stark phase (which scales as the
square of the drive amplitude and is therefore invalidated).

### Variables
* **transmon** (*str*) – The reference for the transmon to target.
* **gate** ( *"sx"* *or*  *"x"*) – The gate to calibrate.
* **repetitions** (*list* *[* *int* *] or* *None* *,* *optional*) – List of repetition counts for the DRAG leakage calibration. If not
  provided, a set of repetitions will be chosen based on the gate.
* **force_rerun** (*bool* *,* *optional*) – Whether to run the routine regardless of the transmon’s current
  calibration status. Defaults to False.
* **run_rb** (*bool* *,* *optional*) – Whether to run a one-qubit randomized benchmarking experiment at the end
  of the routine. Defaults to True.
* **run_stark_phase_cal** (*bool* *,* *optional*) – Whether to run the Stark phase calibration step. Automatically skipped
  when the drive waveform duration is 32 ns or above. Defaults to True.
* **run_voltage_bias_fine_tune** (*bool* *,* *optional*) – Whether to re-tune the flux bias to the sweet spot before calibrating.
  Defaults to False, since the bias is usually maintained separately; when
  disabled the routine starts at the readout classifier.