```python
class boulderopalscaleup.experiments.TransmonFastFluxSpectroscopy(*, transmon, frequencies=CWSIterable(dtype='cws', center=None, width=200000000.0, step=1000000.0), recycle_delay_ns=50000, shot_count=400, spectroscopy_waveform=None, measure_waveform=None, vps, flux_pulse_extra_duration_ns=100, polynomial_order=6, bias_transmon=None, prep_transmon=None, run_mixer_calibration=False, update='auto')
```

Parameters for running a transmon fast-flux spectroscopy experiment.

### Variables
* **transmon** (*str*) – The reference for the transmon to target.
* **frequencies** ([*LinspaceIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/LinspaceIterable.md#boulderopalscaleup.common.LinspaceIterable) *or* [*RangeIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/RangeIterable.md#boulderopalscaleup.common.RangeIterable) *or* [*CWSIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/CWSIterable.md#boulderopalscaleup.common.CWSIterable) *,* *optional*) – The frequencies at which to scan, in Hz.
  Defaults to a scan around the transmon frequency.
* **recycle_delay_ns** (*int* *,* *optional*) – The delay between consecutive shots, in nanoseconds. Defaults to 50,000 ns.
* **shot_count** (*int* *,* *optional*) – The number of shots to take. Defaults to 400.
* **spectroscopy_waveform** ([*ConstantWaveform*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/ConstantWaveform.md#boulderopalscaleup.common.ConstantWaveform) *or* *DragCosineWaveform* *or* *None* *,* *optional*) – The waveform to use in the spectroscopy pulse.
  Defaults to the transmon_spec defcal.
* **measure_waveform** ([*ConstantWaveform*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/ConstantWaveform.md#boulderopalscaleup.common.ConstantWaveform) *or* *None* *,* *optional*) – The waveform to use for the measurement pulse.
  Defaults to the measurement defcal.
* **vps** ([*LinspaceIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/LinspaceIterable.md#boulderopalscaleup.common.LinspaceIterable)) – The flux pulse voltage amplitudes to sweep over.
* **flux_pulse_extra_duration_ns** (*int* *,* *optional*) – Additional duration for the flux pulse in nanoseconds.
  Defaults to 100 ns.
* **polynomial_order** (*int* *,* *optional*) – The polynomial order for data fitting analysis.
  Defaults to 6.
* **bias_transmon** (*str* *or* *None* *,* *optional*) – The reference for a second transmon to apply a simultaneous bias pulse to.
  Defaults to the target transmon.
* **prep_transmon** (*str* *or* *None* *,* *optional*) – The reference for a transmon to excite with an X (pi) pulse at the start of
  each shot (e.g. a spectator, for measuring ZZ shifts). Defaults to None
  (no preparation pulse).
* **run_mixer_calibration** (*bool* *,* *optional*) – Whether to run mixer calibrations before running a program. Defaults to False.
* **update** ( *"auto"* *or*  *"off"* *or*  *"prompt"* *,* *optional*) – How the device should be updated after an experiment run. Defaults to auto.