# boulderopalscaleup.experiments.TransmonAnharmonicity

Source: https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/experiments/TransmonAnharmonicity

```python
class boulderopalscaleup.experiments.TransmonAnharmonicity(*, transmon, frequencies=None, anharmonicity=-200000000.0, recycle_delay_ns=10000, shot_count=400, spectroscopy_waveform=None, measure_waveform=None, run_mixer_calibration=False, update='auto')
```

Parameters for running a transmon anharmonicity experiment.

### Variables
* **transmon** (*str*) – The reference for the transmon to target.
* **frequencies** ([*LinspaceIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/LinspaceIterable.md#boulderopalscaleup.common.LinspaceIterable) *or* [*RangeIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/RangeIterable.md#boulderopalscaleup.common.RangeIterable) *or* [*CWSIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/CWSIterable.md#boulderopalscaleup.common.CWSIterable) *or* *None* *,* *optional*) – The frequencies at which to scan, in Hz.
  Defaults to a scan based on the transmon’s frequency and anharmonicity.
* **anharmonicity** (*float* *,* *optional*) – The guessed anharmonicity of the transmon, in Hz.
  Used to determine the scan frequencies if not provided. Defaults to -200 MHz.
* **recycle_delay_ns** (*int* *,* *optional*) – The delay between consecutive shots, in nanoseconds. Defaults to 10,000 ns.
* **shot_count** (*int* *,* *optional*) – The number of shots to take. Defaults to 400.
* **spectroscopy_waveform** ([*ConstantWaveform*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/ConstantWaveform.md#boulderopalscaleup.common.ConstantWaveform) *or* *None* *,* *optional*) – The waveform to use in the spectroscopy pulse.
  Defaults to a constant waveform with a duration of 2,000 ns
  and an amplitude of 1.5 times the transmon’s x_vp.
* **measure_waveform** ([*ConstantWaveform*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/ConstantWaveform.md#boulderopalscaleup.common.ConstantWaveform) *or* *None* *,* *optional*) – The waveform to use for the measurement pulse.
  Defaults to the measurement defcal.
* **run_mixer_calibration** (*bool* *,* *optional*) – Whether to run mixer calibrations before running a program. Defaults to False.
* **update** ( *"auto"* *or*  *"off"* *or*  *"prompt"* *,* *optional*) – How the device should be updated after an experiment run. Defaults to auto.