# boulderopalscaleup.experiments.CZSpectroscopyByBias

Source: https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/experiments/CZSpectroscopyByBias

```python
class boulderopalscaleup.experiments.CZSpectroscopyByBias(*, control_transmon, target_transmon, waveform='gaussian_flattop', vps, coupler_flux_vp, durations_ns=RangeIterable(dtype='range', start=16.0, stop=200.0, step=8.0), prep_padding_ns=16, measurement_padding_ns=16, recycle_delay_ns=500000, shot_count=200, use_readout_classifier=False, update='auto')
```

Parameters for running a CZ spectroscopy by bias experiment.

### Variables
* **control_transmon** (*str*) – The reference for the transmon to use as control.
* **target_transmon** (*str*) – The reference for the transmon to use as target.
* **waveform** (*str*) – waveform of flux pulse, “constant” or “gaussian_flattop”.
  Defaults to “gaussian_flattop”.
* **vps** ([*LinspaceIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/LinspaceIterable.md#boulderopalscaleup.common.LinspaceIterable)) – The voltage points to sample, in volts.
* **coupler_flux_vp** (*float*) – The flux voltage point for the coupler, in volts.
* **durations_ns** ([*RangeIterable*](https://docs.q-ctrl.com/references/boulder-opal-scale-up/boulderopalscaleup/common/RangeIterable.md#boulderopalscaleup.common.RangeIterable) *,* *optional*) – The pulse durations to sample, in nanoseconds.
  Defaults to RangeIterable(start=16, stop=200, step=8).
* **prep_padding_ns** (*int* *,* *optional*) – The padding to apply before the CZ pulse, in nanoseconds.
  Defaults to 16 ns.
* **measurement_padding_ns** (*int* *,* *optional*) – The padding to apply after the CZ pulse, in nanoseconds.
  Defaults to 16 ns.
* **recycle_delay_ns** (*float* *,* *optional*) – The delay between consecutive shots, in nanoseconds.
  Defaults to 500,000 ns.
* **shot_count** (*int* *,* *optional*) – The number of shots to take.
  Defaults to 200.
* **use_readout_classifier** (*bool* *,* *optional*) – Whether to use a readout classifier for processing the results.
  Defaults to False.
* **update** ( *"auto"* *or*  *"off"* *or*  *"prompt"* *,* *optional*) – How the device should be updated after an experiment run. Defaults to auto.